sk180331 - Issues on a Check Point Appliance when restoring to a factory default image of a Dual Image after an upgrade to R81.20

Issues on a Check Point Appliance when restoring to a factory default image of a Dual Image after an upgrade to R81.20

Product: Check Point Appliances
Version: R81.20
OS: Gaia
Last Modified: 2023-05-21

Symptoms

Solution

Workflow

  1. Revert to the primary factory default image.
  2. Wait for the revert to complete.
  3. Wait for the appliance to boot.
  4. Revert to the secondary factory default image.

Procedure

You can revert to the factory default image in one of these ways:

  1. Enter:

    set fcd revert

  2. Press the SPACE key and the TAB key to see the available default images.

  3. Run:

    set fcd revert <Name of Primary Default Image>

  4. Follow the instructions on the screen.

  5. Reboot:

    reboot

  6. Connect to the command line over the Console port or through the LOM card, if it is installed.

  7. Run:

    set fcd revert <Name of Secondary Default Image>

  8. Follow the instructions on the screen.

  9. Reboot:

    reboot

See sk109047 - How to enter the Boot menu on Gaia OS.

  1. Connect to the appliance through the Console port or through the LOM card, if it is installed.

See the Getting Started Guide for your model. 2. Reboot the appliance. 3. Press any key to get into the Boot Menu. 4. Select the option to restore to the factory defaults with the primary image " fcd_GAIA". 5. Wait for the revert to complete. 6. Wait for the appliance to reboot. 7. Press any key to get into the Boot Menu. 8. Select the option to restore to the factory defaults with the secondary image " fcd_R".