sk180681 - Unable to publish new worksessions
Unable to publish new worksessions
Product: Multi-Domain Security Management, Security Management
Version: R80.40 (EOS), R81 (EOS), R81.10 (EOS), R81.20
OS: Gaia
Last Modified: 2025-01-20
Symptoms
- Unable to publish new worksessions
- The cpm.elg log shows:
[java.util.concurrent.ThreadPoolExecutor@73125ea5[{+}*Running, pool size = 100, active threads = 100, queued tasks = 10000, completed tasks = 37083480*{+}]] did not accept task: com.checkpoint.management.coresvc.CPRunnable@99656b20
Cause
Queued tasks reached the maximum amount threshold and do not get cleared out.
Solution
This problem was fixed. The fix is included in:
- Check Point Quantum R82
- Jumbo Hotfix Accumulator for R81.20 starting from Take 14
- Jumbo Hotfix Accumulator for R81.10 starting from Take 106
- Jumbo Hotfix Accumulator for R81 starting from Take 87
- Jumbo Hotfix Accumulator for R80.40 starting from Take 198
If you choose not to upgrade, Check Point can supply a Hotfix. Contact Check Point Support to get a Hotfix for this issue.
A Support Engineer will make sure the Hotfix is compatible with your environment before providing the Hotfix.
For faster resolution and verification, please collect CPinfo files from the Security Management Server and Security Gateways involved in the case.
Hotfix installation instructions:
Refer to sk168597 - How to install a Hotfix.
NOTE
This solution has been verified for the specific scenario, described by the combination of Product, Version and Symptoms. It may not work in other scenarios.