sk181186 - CPView and 'cpstat' command show different Application Control database versions

CPView and 'cpstat' command show different Application Control database versions

Product: Application Control
Version: R80.40 (EOS), R81 (EOS), R81.10 (EOS), R81.20
OS: Gaia
Last Modified: 2024-06-05

Symptoms

Example for the update from 09 July 2022:

CPVIEW.Software-blades.Overview
|-------------------------------------------------------------------------------------
| Overview SysInfo Network CPU I/O Software-blades Hardware-Health Management Advanced
|-------------------------------------------------------------------------------------
| Overview VPN SSL-Inspection IDA DLP Threat-Prevention Threat-Emulation Advanced ...
|-------------------------------------------------------------------------------------
| Updates Information:
|
|                     Blade status   Last update Number  Update Time
| Application Control enabled        090722_1            09Jul2022 17:42:50
| Anti-Virus          disabled       N/A                 N/A
| Anti-Bot            disabled       N/A                 N/A
| IPS                 disabled       N/A                 N/A

Example for the update from 09 July 2022:

[Expert@MyGw:0]# cpstat appi -f update_status

Update status:           up-to-date
Update description:      Gateway is up to date. Database version: 09072201.
Next update description: The next update will be run as scheduled.
DB version:              09072201

[Expert@MyGw:0]#

Cause

It is the same information, just displayed in a different format.

Solution

This cosmetic problem was fixed. The fix is included starting from:

Check Point recommends to always upgrade to the Recommended version ( Security Gateway / VSX).

NOTE

This solution has been verified for the specific scenario, described by the combination of Product, Version and Symptoms. It may not work in other scenarios.