# Login to SmartConsole fails when the Compliance blade runs scheduled scans

## Symptoms

- Login to SmartConsole fails when the Compliance blade runs scheduled scans. The Compliance blade scheduled scans run at different times.

## Solution

This problem was fixed. The fix is included in:

- [Check Point R82](https://support.checkpoint.com/results/sk/sk181127)
- [Jumbo Hotfix Accumulator for R81.20](https://sc1.checkpoint.com/documents/Jumbo_HFA/R81.20/Default.htm) starting from Take 70
- [Jumbo Hotfix Accumulator for R81.10](https://sc1.checkpoint.com/documents/Jumbo_HFA/R81.10/Default.htm) starting from Take 152

If you choose not to upgrade, Check Point can supply a **Hotfix**. [Contact Check Point Support](https://www.checkpoint.com/support-services/contact-support/) to get a Hotfix for this issue.

A Support Engineer will make sure the Hotfix is compatible with your environment before providing the Hotfix.

For faster resolution and verification, please collect [CPinfo files](http://supportcontent.checkpoint.com/solutions?id=sk92739) from the Security Management Server and Security Gateways involved in the case.

**Hotfix installation instructions:**

Refer to [sk168597 - How to install a Hotfix](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk168597).

**On versions R81.20 and earlier, after you install the Hotfix:**

1. Backup and edit `grc.conf`. Run:
   
   `[Expert@HostName]# cp -pv $MDS_FWDIR/conf/grc.conf{,_BKP}`  
   `[Expert@HostName]# vi $MDS_FWDIR/conf/grc.conf`

2. Remove this line:
   
   `interpreterSchedPeriod=86400`

3. Add these values at the bottom of `grc.conf`:
   
   `interpreterSchedPeriodDay=7`
   `interpreterSchedPeriodHour=23`
   `interpreterSchedPeriodMin=59`
   `interpreterSchedPeriodSec=59`
   
   By default, this schedules the Compliance blade to run every day at 23:59:59.
   
   `interpreterSchedPeriodDay` is the day of the week. 0=Sunday, 1=Monday, 2=Tuesday, 3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday, 7 = every day.
   
   `interpreterSchedPeriodHour` is the hour of the day which can be between 0-23.
   
   `interpreterSchedPeriodMin` and `interpreterSchedPeriodSec` can be between 0-59.

4. Save the changes in the `Vi` editor and restart the `fwm` process to apply the changes.

**On version R82** For R82 the necessary configuration is already included in `$MDS_FWDIR/conf/grc.conf`.

#### NOTE

This solution has been verified for the specific scenario, described by the combination of Product, Version and Symptoms. It may not work in other scenarios.