# Multiple SNMP OIDs return incorrect data types

**Product**: Security Gateways, Security Management  
**Version**: R81.20, R82  
**OS**: Gaia  
**Last Modified**: 2025-08-04

## Symptoms

- When querying some Simple Network Management Protocol (SNMP) Object Identifiers (OIDs), the responses do not match the expected data types as defined in the Management Information Base (MIB) specifications.

**Notes**:

- The issue occurs on multiple OIDs.
  - The issue is not limited to a specific Gateway.
  - The returned data type does not match the expected MIB definition. For example, an integer may be expected, but the response contains a string.
  - For more information about SNMP MIB files, see [sk90470](https://support.checkpoint.com/results/sk/sk90470).
- Below is an example of a "Wrong Type" in the response:
```
snmpwalk -m /opt/CPsuite-R81.20/fw1/lib/snmp/chkpnt.mib -v2c -c  localhost identityAwarenessAuthUsers
CHECKPOINT-MIB::identityAwarenessAuthUsers.0 = Wrong Type (should be INTEGER): Gauge32: 4521
```

## Cause

Some OIDs in the `chkpnt.mib` file are incorrectly defined. This mismatch causes incorrect data types in SNMP responses.

**Note**: The `chkpnt.mib` file contains definitions of all SNMP counters supported by Check Point software. These definitions are used to manage and monitor Check Point devices through SNMP.

## Solution

This problem was fixed. The fix is included in:

- [Jumbo Hotfix Accumulator for R82](https://sc1.checkpoint.com/documents/Jumbo_HFA/R82/Default.htm) starting from Take 36
- [Jumbo Hotfix Accumulator for R81.20](https://sc1.checkpoint.com/documents/Jumbo_HFA/R81.20/Default.htm) starting from Take 111
- [Jumbo Hotfix Accumulator for R81.10](https://sc1.checkpoint.com/documents/Jumbo_HFA/R81.10/Default.htm) starting from Take 177

If you choose not to upgrade, Check Point can supply a **Hotfix**. [Contact Check Point Support](https://www.checkpoint.com/support-services/contact-support/) to get a Hotfix for this issue.

A Support Engineer will make sure the Hotfix is compatible with your environment before providing the Hotfix.

For faster resolution and verification, please collect [CPinfo files](http://supportcontent.checkpoint.com/solutions?id=sk92739) from the Security Management Server and Security Gateways involved in the case.

**Hotfix installation instructions:**

Refer to [sk168597 - How to install a Hotfix](https://supportcenter.checkpoint.com/supportcenter/portal?eventSubmit_doGoviewsolutiondetails=&solutionid=sk168597).

#### NOTE

This solution has been verified for the specific scenario, described by the combination of Product, Version and Symptoms. It may not work in other scenarios.

## Article Properties

**Access Level**: General  
**Status**: Approved by TAC  
**Date Created**: 2025-03-17  
**Last Modified**: 2025-08-04
