Symptoms
- Adding IoC feed from the CLI fails with an error "Can not load indicators feed without AV & AB Blades enabled, please enable AV & AB and try again", although the Anti-Virus and Anti-Bot blades were enabled in a Quantum Maestro environment.
Cause
The Anti-Virus blade failed to load IoC feeds. Although Anti-Virus and Anti-Bot were enabled on Maestro, the users receive an alert indicating that the blades were disabled.
Solution
This problem was fixed. The fix is included in:
- Jumbo Hotfix Accumulator for R81.20 starting from Take 126
If you choose not to upgrade, Check Point can supply a Hotfix. Contact Check Point Support to get a Hotfix for this issue.
A Support Engineer will make sure the Hotfix is compatible with your environment before providing the Hotfix.
For faster resolution and verification, please collect CPinfo files from the Security Management Server and Security Gateways involved in the case.
Hotfix installation instructions:
Refer to sk168597 - How to install a Hotfix.
NOTE
This solution has been verified for the specific scenario, described by the combination of Product, Version and Symptoms. It may not work in other scenarios.